Repair monitors SONY
SONY CPD-100EST image changes periodically in brightness. Flashing images.
PC: S035 defective
pF/2kV 10000. When flashing, the voltage on the R064 lies within the
boundaries of 550-630V.
SONY CPD-100EST No picture. LED lights. 1.2 kV CN301
Boards keniskopa absent.
MP: R552 defective 2.2
Ohm
MP: R534 defective .01 uF
SONY CPD-100EST In this paper, the image
becomes darker.
PC: Q001 is defective
2SC5022-02 Poor Murieta device. Fault manifests itself during heating and
Cooling of the transistor.
SONY CPD-100EST When there is a surge of high voltage. LED lights green for
about 2 seconds, then flashes orange.
MP: short legs № 7 chip IC401
and R424 .
SONY CPD-100EST When there is a surge of high voltage. LED lights green for
about 2 seconds, then flashes orange.
MP: S583 faulty 0.022 mF/100V.
SONY CPD-100GST When enabled, the LED blinks green. High voltage is 2-3
seconds, then LED blinking orange.
MP: Q507 is defective BU2522AX.
SONY CPD-100GST device will not turn on, the LED is dark. Pressing the
contrast of "+" or "-" picture appears.
MP: IC905 defective
24LC08BT/SN. (EPROM lost data) can popytatsya write a new program and configure
the device.
SONY CPD-100GST high voltage is, the LED lights. On loss of signal cable, the
display shows the table "No input Signal" (table shaking slightly in
the vertical) Pressing the contrast "- appears white picture, but when you
click" + "kontarstnost, there is a table of" red green blue
"
MP: IC901 defective CXD8692S/CYR (8-759-478-69)
SONY CPD-100GST No high-voltage LED lights
up the sound is.
MP: connective path between R541
and R568 is damaged.
SONY CPD-100GST No picture. LED lights, high voltage there.
PSU: D615 defective EGP20DPKG23
R622 is defective 0,47 Om / 1,2 W
SONY CPD-100GST When the LED is not lit. Line transformer
tselkaet. S610 heavily loaded.
MP: Q507 is defective BU2522AX 8-729-041-29
Q520 is
defective or IRFI9620G_S J449 (8-729-042-23)
SONY CPD-100GST The blue color is missing.
KP: leg number 11 chip IC002 has a bad contact.
SONY CPD-100GST sometimes disappears
image.
PC: leg number 8 plug SN305 has a bad contact. + 5V
SONY CPD-100GST Red absent. Or by pressing the «Reset» picture flashes and
becomes red for a split second.
PC: IC001 defective CXA2055P (8-752-076-89)
SONY CPD-200EST When the image is, but if you press the "+"
brightness, brightness decreases. Increase the contrast function does not work.
After about 10 minutes, the image becomes unstable, swims and jumps.
MP: IC901 faulty ST7272N5B1/CUS
SONY CPD-200EST When enabled, the LED is green a couple of seconds, then
blinking orange.
MP: IC901 faulty ST7272N5B1/CUS
SONY CPD-200EST No picture. The device snaps loudly or quietly. LED remains
dark. S620 is strongly charged.
PC: IC002 defective LM2405T
SONY CPD-200EST image shakes and floats.
PSU: S620 defective 330mF/400V
SONY CPD-200EST picture pulsates. Quickly becomes large and decreases
rapidly.
MP: RV501 has a bad contact.
SONY CPD-200EST No picture. LED lights.
MP: D526 is defective.
SONY CPD-200EST appear on the image strip. Can be permanently or appear
remarks through time. Bands are clearly visible on a white background.
MP: IC401 defective TDA8172.
SONY CPD-200EST Totally
not working. Fuse F601 defect.
PSU: D601 defective GBU4JL.
SONY CPD-200EST When the relay clicks. LED blinks green. Fault manifests
itself through time, often in the cold.
PSU: R659 defective
390kOm. In this failure, this resistor increases its RESISTANCE (eg 470kOm)
SONY CPD-200EST Image has a lightweight geometric distortions in the form of
concave edges. If the brightness at maximum, there are horizontal stripes.
MP: Q502 is defective IRFU214.
SONY CPD-200EST No high voltage. LED is
dark. PSU clicks.
MP: Q507 , Q503 and Q502 are faulty.
SONY CPD-200EST judder.
Metallic screen has no connect with the masses.
SONY CPD-200EST Image negatively noticeable shadows towards the right.
PC: R018 is defective.
Leg number 2 and the leg number 1 plug CN309 has a short circuit.
SONY CPD-200EST No picture. LED vseti, glow keniskopa there.
MP: R552 and C534 are faulty.
SONY CPD-200EST Sometimes there is a table menu «H-Center» All of the buttons
on the left of the button «Center» do not work.
MP: JW133 has short to ground.
SONY CPD-200EST When there is a surge of high voltage. LED lights green for
about 2 seconds, then flashes orange.
MP: Q503 , C582 and D903 are faulty.
SONY CPD-200EST absence of one of the
colors (eg green)
MK: FB201 defective.
SONY CPD-200EST image is dark, almost nothing can be seen only on the left
side of the image visible.
PC: IC003 defective SNY425.
SONY CPD-200EST device is not working. LED glow keniskopa and high voltage
is. No picture, but Sometimes the image appears.
PC: SN306 has a bad contact.
SONY CPD-200EST When enabled, the LED is green a couple of seconds, then
blinking orange.
MP: IC904 TDA9105 faulty
SONY CPD-200EST color contamination in the left side of the screen. Loop
degaussing for the demagnetizing.
Keniskop defective M41LKN70X
SONY CPD-200EST image darkens over time.
PC: Q001 is defective
2SC5022-02 is easy to identify the thermal effect.
SONY CPD-200EST completely not working, the LED is dark. PSU clicks (quietly)
PSU: R659 defective 390kOm.
SONY CPD-200EST When there is a surge of high voltage. LED lights green for
about 2 seconds, then flashes orange. After that, hear quiet clicks.
MP: IC401 defective TDA8172.
SONY CPD-200EST One of the colors
available.
PC: IC002 defective LM2405T.
SONY CPD-200EST sync with many frequencies is not working properly. Vertical
lines are not straight, and wavy. Jitter and the various obstacles.
MP: IC901 faulty ST7272N5B1/CUS.
SONY CPD-200EST vertical black bars on the left of the image. Incorrect
geometry images.
MP: D903 defective HSS82.
SONY CPD-200EST device is switched off in standby mode. Pulses «V Fly Back»
feet № 49 № 20 processor available.
MP: IC401 defect TDA8172.
SONY CPD-200EST unit off after 5 minutes. In the picture there is no
distortion, probably only possible at certain frequencies fault manifests
itself.
MP: Q512 is defective.
SONY CPD-200EST No picture, BP clicks.
MP: C534 defective.
SONY CPD-200EST When enabled, the LED is green a couple of seconds, then
blinking orange.
MP: Q502 and R509 are faulty.
SONY CPD-200EST image offset in the
western side.
MP: S810 has a bad contact.
SONY CPD-200EST image rotation is not
possible.
MP: IC400 and R408 are faulty.
SONY CPD-200EST image is distorted, shaking. Manifestation of poor contact.
MP:
C973 has a bad kontkt.
Sony
PVM-9221ME Vertical Sync narashena. Footage running on
the screen. Regulator of «H-Hold» is not regulated.
Fee Adjustments: RV516 faulty 203V