MSA مشرف عام
عدد المساهمات : 541 تاريخ التسجيل : 16/06/2010
| موضوع: service-mode -ONIKS الخميس مايو 05, 2011 4:57 pm | |
| Onyx 54TTS12-22 Slim chassis PF2178H/4420 Processor - LA76936N-7N RC - ES-21514C Login in the service - a hidden button F (Factory) on the remote. (MENU) on the remote control - selection page (ADJUST) Clicking on the button (F): 1 times - "FACTORY" 2 times - "B / W BALANCE" 3 times - "ADJUST MENU 0" 4 time - "BUS OPEN" 5 times - Exit the service mode.
Onyx 14 "chassis KM060301-026942 Processor - NTDA9381C38NC Onyx 54TTS12-06P chassis TC2106HUE Processor - NTDA9381C38NC Onyx 54TTS12-77P (06) Chassis F2177HUE Processor - NTDA9381C38NC Login in the service - click on the remote control buttons in the following sequence: MENU, 8, 5, 0, 0 Exit - Button "POWER" on the RC
Onyx 37TTS14-13 (14) CPU - A8821 TV service mode by using the regular remote control For login in the service menu to adjust the volume on the TV at least. On the remote control button (DIS). TV enters the service mode S. Pressing the button (DIS) will translate the TV in service mode D.
Onyx 54TTS12-9 (10p) Processor - 8851CPNG (EAS) Login in service mode D-MODE. Press the D-MODE ON / OFF on a dedicated console. On the screen in the upper right corner shows a letter D. Left in the upper right corner will be a parameter and its value. Login in service mode with a standard remote control. Click on the V-TV and set the volume to 00. Hold the button on the TV remote control, press the button [_ +] On display in the upper right corner shows a letter S (You are logged in the service mode S) After completion of adjustment in the S mode for Released from it need to turn off the TV. When re-entry procedure in the service mode you can enter in the most "complete" service mode D-MODE.
Onyx 54TTS12-15 chassis PF2118/FS2198 «CHA» Philips Login in the service - The TV set the volume to minimum. On the remote control to press the MUTE button and holding it press the button on the TV MENU. To clear the memory in the service mode, press the button on the remote control 8. Select INIT. Use the PROG + set INIT BUSY. After 5 seconds, BUSY is cleared. TV is off the network and turned on. Memory is cleared and ready for new installations. NOTE: When you click on the button 9 and the choice of INIT, all previously recorded values in memory can be erased. To initialize, press the 9 button on the remote. Select the active state - 1. Once again, store the required values.
Onyx 54TTS12-19, 36, 38, 98 chassis 21VM32 Service mode D. 1. TV service mode by using the regular remote control K10N-C10 2. For login in the service menu to adjust the volume on the TV at least. On the remote control to press the MUTE button and holding it press the button on the TV MENU. TV enters the service mode D. 3. The buttons on the remote control: GREEN - Select the option to adjust the DOWN RED - Select the option to adjust the UP YELLOW - Select a minus. BLUE - Select a plus. 4. When you click on the MUTE button on the remote control will be a narrow strip on the screen needed to set the accelerating voltage. 5. When you press the button on the remote control P. MODE appears AFT and 5 seconds later appears AFT OK 6. When pressed on the remote control SLEEP button appears on the screen MENORY RECAL and all factory installation reset. After this procedure, you must re-write the values to
Onyx 54TTS12-30P chassis PF21300 Processor - TDA9384PS/N3/3 Onyx 54TTS12-91P chassis PF21S91 Processor - TDA9381PS/N3/3 Login in the service - The TV set the volume to minimum. On the remote control to press the MUTE button and holding it press the button on the TV MENU. TV will go into service mode.
Onyx 63-84TTS11-19-80 chassis CH-10D Onyx 63TTS11-19P chassis CH-10D Onyx 63TTS11-86 chassis CH-10D Onyx 72TTS11-19_80_86_99P chassis CH-10D Onyx 84TTS11-80 chassis CH-10D Login in the service - Using RC K11 series. Set the "Volume" to a minimum. Press MUTE on the remote control. Hold down the MUTE button press the MENU button on the TV until the red symbol S appears on the TV screen. After the TV input to a service mode, press CAL on the remote. Press the MENU I choose or I needed to adjust the setting. Press the MENU ---- or ---- set the required settings. Rotating core of L 066 to set the optimal size of the menu on the TV screen. Exit - Off. TV.
Onyx model 2519, 2910 Chassis CH-10 First of all go to the regime SERVICE. Then, by pressing the «Cal» key on the remote control, change the set. Each press on the remote control button "MENU ↑» or "Menu ↓» will change positions in the selected page. Clicking on the remote control button "MENU →» or "MENU ←» will be accompanied by changes in the parameters of the selected position. By pressing the remote control or turn off the TV receiver box to exit the service mode.
Onyx 63TTS11-15P chassis «CHA» Philips Login in the service - The TV set the volume to minimum. On the remote control to press the MUTE button and holding it press the button on the TV MENU. Memory initialization. To clear the memory in the service mode, press the button on the remote 9. Select INIT. Use the PROG + set INIT BUSY. After 5 seconds, BUSY is cleared. TV off. from the net and incl. Memory is cleared and ready for new installations.
Onyx 63TTS11-91 chassis PF29E91 Processor CH08T0605 / 8827CSNG5BKO Onyx 72TTS11-18 chassis PF29E91 Processor CH08T0605 / 8827CSNG5BKO Onyx 84TTS11-15P chassis PF3415E Processor CH08T0605 / 8827CSNG5BKO Onyx 84TTS11-96 chassis PF3415E Processor CH08T0605 / 8827CSNG5BKO Entrance in the service - should be on a TV set volume to minimum. On the remote control to press the MUTE button and holding it press the button on the TV MENU. TV enters the service mode D.
Onyx 63TTS12-15P chassis PF2118/FS2198 «CH» Philips Processor TDA9384PS/N3/2/1615 Login in the service - on the TV set the volume to minimum. On the remote control to press the MUTE button and holding it press the button on the TV MENU. Memory initialization. To clear the memory in the service mode, press the button on the remote 9. Select INIT. Use the PROG + set INIT BUSY. After 5 seconds, BUSY is cleared. TV off. from the net and incl. Memory is cleared and ready for new installations.
Onyx 72TTS11-06P chassis TF2906HU-HIS Processor TDA9384/N3/3 Onyx 72TTS11-20 chassis TC2919HUE-HIS Processor TDA9384/N3/3 Onyx 84TTS11-06P chassis TF3406DU-HIS Processor TDA9384/N3/3 Onyx 84TTS11-20 chassis TF3419HUE-HIS Processor TDA9384/N3/3 Login in service: On a dedicated console, click VG2. In the upper left corner of the screen will display MUTE. On a dedicated remote control, press M. In the upper left corner of the screen beech M. On a dedicated console, click LOGO. Appears on the TV logo. Press the P + / P-establish the necessary letter and keys V + / V-choose familiarity subject to revision. Press button 1 on the remote. Appears on the TV MENU: Press the P + and P-select option, and the buttons "Volume" Over / Under set the desired value. Memory initialization. NOTE: When you click on the initialization, all previously recorded values in memory will be erased. To initialize the menu bar, select INIT. Select the active state --- 1. Once again, store the required values. To exit the service mode, click on the dedicated remote control button on the MI screen in the upper left corner will display MUTE. Click on the specials. Remote control button VG2, TV out of service mode.
Login a service by using the user remote control. Click the series with a slight pause on the remote MUTE, CALL, 9, 8, 0 Exit - POWER OFF on the remote.
Onyx 72TTS11-90 chassis CJ20A Processor A8821 Login in the service - on the TV set the volume to minimum. On the remote control button DIS TV will enter the service mode S. Pressing the button DIS translate TV in service mode D
Onyx 84TTS11-90 Chassis CTV-5 «CANCA-THOMSON» Login - Press the button on the remote SERVICE. Appears on the TV table 1. Press the P + / P-select parameters to be adjusted, but the buttons V + / V-set desired value The transition between the tables - click on the OK button remote control Note: to record changes of positions in the options, click the RR on the remote. Exit - Button "PP" on the remote.
Onyx 97TTS15-98 chassis 5P60 Login - On the remote control to click on the queue button: CLOCK, PM, O TV will go into service mode. Buttons 0-9 select one of the tables to adjust the parameters. Press PROG + and PROG-select the line to adjust Press the VOL + and VOL-set desired value Exit the service mode - press the (+) button on the remote.
Onyx 97TTS15-99 Chassis 5N11 & 5N07 SKYWORTH (PANASONIC) Login in service mode. 1-1. There are two variants of initialization EEPROM. A. Press the buttons simultaneously VOL + VOL - on the TV and turn on the TV. Then press the "MENU" button to switch to code option (Option Code). Appears on the TV image: 1 2 3 4 5 6 7 8 9 A (red) * * * * * * * * * * (Green) B. Once the TV is on, press the button «factory», then press "MENU" button. In the center of the screen there will be ten numbers (Option Code Menu). 1-2. Press «PM» and «SM» on the control panel simultaneously until «INITIAL PART OK» (which means the memory, the former partially initialized. Repeat several times, if the picture has no changes
Onyx 97TTS15-99 Chassis 5N11 & 5N07 SKY (PANASONIC) The remote control must be further developed 1. Install an additional button NO contact 11 and 27. This button is called SCREEN and serves to set the accelerating voltage on the CRT. 2. an extra button open contact 14 and 27. This button is called FACTORY and serves to convert the TV into service mode. There are two variants of initialization EEPROM. Option A. In the modified remote control button FACTORY. Option B. Push buttons simultaneously VOL + VOL-on the TV and keeping them down the turn on the TV network button on the TV. After several seconds appears on the TV MENU RF AGC (AGC level) --------------------------- 45 VIF DET NEG (LEVEL DETECTOR) -------------- 2D RGB LIMIT (BRIGHTNESS MENU) ----------------------- 7 BLUE BACK (BLUE SCREEN) ----------------------- ON OSD.H (POSITION MENU) ---------------- D Use the PROG + and PROG-on remote control select line subject to adjustment, and by pressing the VOL + and VOL-set desired value.
| |
|